EH818 HOUSE ELECTRICAL SIMULATION TRAINING SYSTEM

3,616.00 (4,447.68 Tax Included)

Electrical house simulation training system.

Out of stock

Categories: SKU: 117432

Features:

  • Represent a small size building for residential use
  • Analyze the correct procedures mounting such as:
    1. Light and EMF distribution systems with energy counter (kWh)
    2. Stair light system
    3. Interphone system
    4. Protective earth and equipotential system
  • Testing of electrical installations according to the international (IEC) standards.
  • Measure insulation, fault loop, impedance and voltage drop
  • Execute continuity tests and checking of the protection devices on already wired and operative circuits
  • Carrying out changes and transformations on already existing installations.
Catalog Number

117432

Specifications

.Mechanical characteristics
.Build in welded, chemically treated and epoxy painted sheet steel
.Each of the 4 available walls, several electrical and electronic components, embedded into flush  mounted junction boxes, are placed over hinged panels
.Whole structure is set on a wheel mobile base

Dimensions (W x H x D): 880 x 1300 x 800 mm
Weight: 100kg

Wall 1 (main entrance)

.1 Main power supply 230 V 16 A
.1 Single-phase energy counter 230 V 20 A
.1 Switchboard with earth leakage circuit brake and 3 thermal-magnetic circuit breakers
.1 Interphone porter with 2 pushbuttons and 2 illuminated name-plates
.1 Electric lock
.1 Equipotential protective earth collector
.1 Ground connections with 1-ohm resistor and sectioning terminals

Wall 2 (sitting room and kitchen)

.1 Light installation with incandescent lamps 230V controlled by 2 pushbuttons and step-by-step relay
.2 Outlets 230V 16A for sitting room users
.1 Incandescent lamp 230V with dimmer
.1 Door bell
.1 Thermostat (day-time area)
.1 Low energy consumption lamp controlled by two-way switches
.2 Outlets 230V 16 A for electric household appliances
.1 Interphone communicating with the gate porter
.1 Buzzer for calls from bathroom

Wall 3 (bedroom and bathroom)

.1 Incandescent lamp controlled by 2 two-way switches and 1 intermediate switch
.1 Outlet 230V 16A for electrical household appliances
.1 Single-phase outlet 230V 10A for the lights
.1 Thermostat (night-time area)
.2 Pushbuttons for service call
.1 Pushbutton for emergency calls from the bathroom
.1 Thermostat (bathrooms)
.1 Outlet 230V 16A for boiler supply.

Wall 4 (office, stairwell, heating plant)

.2 Lamps with switch
.1 Outlet 230V 16A for electric household appliances
.1 Single-phase outlet 230V 10A for lights
.1 Interphone communicating with the gate porter
.1 Incandescent lamp 230V with two pushbuttons and time relay
.1 Outlets 230V 16A for heating plant
.3 Pilot lamps (simulation of water pumps for different heating areas)