FINE BEAM TUBE SYSTEM

1,408.001,510.00

Fine beam tube system.

Objects
Deflection of electrons in a closed circular path inside a magnetic field
Determination of specific change of an electron e/m

 

Principles
The fine beam tube is used for investigating the deflection of cathode rays in a uniform
magnetic field produced by a pair of Helmholtz coils (P338001). In addition, it can also be used for quantitative
determination of the specific charge of an electron e/m.

Located inside a glass bulb with a helium residual gas atmosphere is an electron gun, which
consists of an indirectly heated oxide cathode, a Wehnelt cylinder and a perforated anode. The gas atoms are ionized along
the path of the electrons and a narrow, well-defined, luminescent beam is produced. Incorporated measurement marks
facilitate a parallax-free determination of the diameter of the circular path of the beam deflected in the magnetic field.

Specifications

SYSTEM A – BASIC FINE BEAM TUBE SYSTEM

A.jpg
SYSTEM COMPOSITON
1 pc Fine beam tube P318001
1 pc Fine beam tube base P328001
1 pc Helmholtz pair of coils P338001
1 pc DC power supply M10-QP500E

 

                       SYSTEM B – COMPLETE FINE BEAM TUBE SYSTEM

 

SYSTEM COMPOSITON
1 pc fine beam tube P318001
1 pc fine beam tube base+ Helmholtz pair of coils P328002
1 pc DC power supply M10-SPN300-03C
1 pc DC power supply M10-SPN110-01C
1 pc DC power supply M10-SPM18-3C
    FINE BEAM TUBE P318001
Gas filling:
Gas pressure:
Filament voltage:
Filament current:
Focus voltage:
Anode voltage:
Anode current:
Circular path diameter:
Division spacing:
Tube diameter:
Total length:
Weight:
Helium
1.3hPa
4~10V AC/DC
600mA at 6.3V
-50V
200~300V
<0.3mA
20~100mm
10mm
160mm
255mm
0.35kg