SDO2000 SERIES CLASS & ROOM TYPE DIGITAL STORAGE OSCILLOSCOPE

416.00654.00

Class & room type digital storage oscilloscope.

Categories: SKU: N/A

Features:

  • 70MHz/100MHz/200MHz bandwidth
  • Independent double time base
  • AUTO’s strategy presetable
  • Lissajous figure supported
  • Automatic measurement of 34 waveform parameters
  • Automatic cursor tracking measurement function
  • 2 channels, low noise floor, wide vertical range: 1mV/div~20V/div
  • Built in FFT and digital filter
  • System software upgrade via USB drive
  • 7 inches TFT LCD, high resolution display 800X480
  • Delicate window extension function and precise analysis on waveform details and overview
  • Supports plug-and-play USB storage device; communication with and remote control of computer through the USB device

Specifications

Technical Data SDO2072 SDO2102X SDO2202X
Real-time Sample Rate 2500MS/s 1GS/s 1GS/s
Equivalent Sampling Rate 50GS/s
Average Sampling Times 2,4,8, 16, 32, 64, 128 and 256
Input Channel Specifications
Input coupling DC, AC, GND
Input Impedance (1MΩ±2%)//(18pF±3pF)
Probe attenuation coefficient 0.01x/0.02×/0.05×/0.1×/0.2×/0.5×/1×/2×/5×/10×/20×
50×/100×/200×/500×/1000×
Maximum input voltage 300 Vrms, the transient over voltage is 1000 Vpk.
Horizontal System Specification
Time-base scale 2ns/div-50s/div
Waveform interpolation Sin(x)/x
Time-base accuracy ≤±(50+2×service life)ppm
Record length 2×512k sampling point
Storage depth Single channel: 64kpts, Double channel: 32kpts
Sampling rate and delay time accuracy ±50ppm (any time interval≥1ms)
Measurement accuracy of
time interval (△T)
Single : ±(1 sampling time interval + 50ppm x reading + 0.6ns)
>16 average values: ±(sampling time interval+50ppmXreading+0.4ns)
Waveform capture rate 5,000 wfms/s
Vertical System Specification
Analog Bandwidth 70MHz 100MHz 200MHz
Rise Time(Typical) ≤7ns ≤3.5ns ≤1.8ns
Channels 2
Analog-to-digital converter (A/D) 8 bits
Deflection factor range 1mV/div~20V/div(1MQ)
Position range ≥±8div
(Typical) limitation bandwidthSelectable 20MHz
Low frequency response
(AC Coupling, -3dB)
≤5Hz(above BNC)
DC gain accuracy 5mV~20V/div:≤±3%,1mV~2mV/div:≤±4%
DC measurement accuracy When vertical position is 0 and N≥16:
±(4%Xreading+0.1div+1mV) and selects 1mV~2mV/div;
±(3%Xreading+0.1div+1mV) and selects 10mV~20V/div
When vertical position is not 0 and N≥16:
±(3%×(reading + vertical position reading) +
(1%Xvertical position reading)+0.2div);
The setting from 5mV/div to 200mV/div plus 2mV,
the setting value from 200mV/div to 20V/div plus 50mV
Measurement accuracy of
voltage difference (△V)
(average sampling mode)
Under the same setting and environment conditions and
after averaging the captured waveforms with a quantity of
≥16, the voltage difference ( △V) between any two points on
the waveform: ±(3%Xreading+0.05div)
Trigger System Specification
Trigger sensitivity ≤1div
Range of trigger level Int: From the screen center ±10div, Ext: ±3V
Trigger level accuracy (typical)
(Signal with rising and falling time≥20ns)
Int: ±(0.3divXV/div) (within±4 div from the screen center)
Ext:±(6% setting value+40mV)
Pre-trigger capacity Normal mode/scan mode, pre-trigger/delay trigger
the pre-trigger depth is adjustable
Hold-off range 80ns~1.5s
Set the level to 50% (Typical) Operate under the condition of input signal frequency of ≥50Hz
Trigger mode Auto, Normal, Single, Edge, Pulse, Video, Slope
High-frequency hold off Hold off signals over 80kHz
Low-frequency hold off Hold off signals below 80kHz
Measurements
Cursor Manual mode Voltage difference between cursors (△V),
Time difference between cursors (△T),
Reciprocal of Δ Τ (Hz) (1/ΔΤ)
Track mode waveform of point of value time and valueVoltage
Auto mode Cursor display is allowed on auto measurement mode
Automatic measurement Max, Min, High, Low, Ampl, Pk-Pk, Middle, Mean, CycMean, RMS,
CycRMS, Period, Freq, Rise, Fall, RiseDelay, FallDelay, +Width, -Width,
FRFR, FRFF, FFFR, FFFF, FRLF, FRLR, FFLR, FFLF, +Duty, -Duty,
Area, CycArea, OverSht, PreSht and Phase.
Measurement quantity Display 5 types of measurement at the same time
Measurement scope Screen or cursor
Math
Math operation +, -, x, +
Window Rectangle, Hanning, Blackman, Hamming
Vertical scale Vrms, dBVrms
Digital filtering Low pass, High pass, Band pass, Band reject
Trigger frequency meter
Reading resolution 6bits
Trigger sensitivity ≤30Vrms
Accuracy (Typical) ±51ppm (+1 character)
Storage Internal: 20 groups. USB: 200 groups
Display 7-inch 800X480 color LCD
Interface Standard: USB Host, USB Device, EXT Trig,Pass / Fail. Option: LAN
Power 100V~240VACrms, 50/60Hz, CAT II
Size 306mm(W)×138mm(H)X124mm(D)
Weight 2.5kg

Catalog Card

Download

Do you need more information? We are at your disposal!